Welcome to Sielco Sistemi Store!

SS 10016 Distributed I/O device in 6 DIN box 4 inputs for mV and Thermocouples over RS-485

Be the first to review this product

Availability: Available in 3-5 days

€140.00

Quick Overview

Analog module with 4 thermocouple inputs

SS10016

  • Details

    General description

    The device SS10016 converts up to 4 analogue input signals into engineering units in digital format. The data are transmitted with MODBUS RTU/ASCII protocol over the RS-485 network.
    It is possible to connect on input 4 voltage signals up to ± 250 mV or thermocouples sensor type B, E, K, J, N, R, S, T. By programming, it is possible to execute the scaling of the measure of input up to ± 32768 points obtaining in the dedicated registers the measure of the channel in the desired format.
    The device guarantees high accuracy and stable measure versus time and temperature.
    To ensure the plant safety, a Watch-Dog timer alarm is provided.
    The isolation between the parts of circuit removes eventual ground-loop effects, allowing the use of the device even in the heavy environmental conditions.
    The device is housed in a 6 module DIN rough self-extinguishing plastic box for mounting on EN-50022 standard DIN rail.

    Main features

    • Modbus Slave device on RS-485
    • Modbus RTU/ Modbus ASCII protocol
    • 4 input channels for voltage up to ± 250 mV and thermocouples sensor type B, E, K, J, N, R, S, T
    • Communication parameters configurable by dip-switches
    • Watch-Dog Alarm
    • Remotely Configurable
    • 1500 Vac 3-ways Galvanic Isolation
    • LEDs of signalling on front side for power supply and communication
    • Connection by removable screw terminals
    • High Accuracy
    • CE mark
    • DIN rail mounting in compliance with EN-50022

    Manuals and guides

    Datasheet SS 10016Datasheet SS 10016
    User Guide SS 10014User Guide SS 10016
    IOLOG LeafletIOlog series illustrative leaflet
    IOLOG LeafletCE Declaration of Conformity
    Webser I/O ModulesIndustrial I/O Modules

  • Additional Information

    Communication protocol Modbus ASCII, Modbus RTU, Modbus TCP (using SS10580 converter)
    Insulation voltage 1500 Vca @ 50 Hz for 1 minute between inputs, outputs, serial and supply
    EMC Immunity conform to EN 61000-6-2
    EMC Emissions conform to EN 61000-6-4
    Supply voltage from 10 to 30 VDC
    Maximum current consumption 45 mA @ 24 VDC
    Polarity inversion protection maximum 60 VDC
    Temperature operating environment from -10 to +60 ºC
    Humidity operating environment from 0 to 90 % (non condensing)
    Storage temperature from -40 to +85 ºC (without ice)
    Material self-extinguishing plastic
    Mounting on EN-50022 DIN rail
    Weight about 200 g
  • Tags

Details

General description

The device SS10016 converts up to 4 analogue input signals into engineering units in digital format. The data are transmitted with MODBUS RTU/ASCII protocol over the RS-485 network.
It is possible to connect on input 4 voltage signals up to ± 250 mV or thermocouples sensor type B, E, K, J, N, R, S, T. By programming, it is possible to execute the scaling of the measure of input up to ± 32768 points obtaining in the dedicated registers the measure of the channel in the desired format.
The device guarantees high accuracy and stable measure versus time and temperature.
To ensure the plant safety, a Watch-Dog timer alarm is provided.
The isolation between the parts of circuit removes eventual ground-loop effects, allowing the use of the device even in the heavy environmental conditions.
The device is housed in a 6 module DIN rough self-extinguishing plastic box for mounting on EN-50022 standard DIN rail.

Main features

  • Modbus Slave device on RS-485
  • Modbus RTU/ Modbus ASCII protocol
  • 4 input channels for voltage up to ± 250 mV and thermocouples sensor type B, E, K, J, N, R, S, T
  • Communication parameters configurable by dip-switches
  • Watch-Dog Alarm
  • Remotely Configurable
  • 1500 Vac 3-ways Galvanic Isolation
  • LEDs of signalling on front side for power supply and communication
  • Connection by removable screw terminals
  • High Accuracy
  • CE mark
  • DIN rail mounting in compliance with EN-50022

Manuals and guides

Datasheet SS 10016Datasheet SS 10016
User Guide SS 10014User Guide SS 10016
IOLOG LeafletIOlog series illustrative leaflet
IOLOG LeafletCE Declaration of Conformity
Webser I/O ModulesIndustrial I/O Modules

Additional Information

Communication protocol Modbus ASCII, Modbus RTU, Modbus TCP (using SS10580 converter)
Insulation voltage 1500 Vca @ 50 Hz for 1 minute between inputs, outputs, serial and supply
EMC Immunity conform to EN 61000-6-2
EMC Emissions conform to EN 61000-6-4
Supply voltage from 10 to 30 VDC
Maximum current consumption 45 mA @ 24 VDC
Polarity inversion protection maximum 60 VDC
Temperature operating environment from -10 to +60 ºC
Humidity operating environment from 0 to 90 % (non condensing)
Storage temperature from -40 to +85 ºC (without ice)
Material self-extinguishing plastic
Mounting on EN-50022 DIN rail
Weight about 200 g